SYSmark 2004 SE Known Issues

As of SYSmark 2004 SE release, the following issues were known. If you are encontering an issue not documented here, please check the BAPCo web site or send an error report.

1.0 Installation Issues

   1.1 Operating Systems:
Windows 98 Second Edition (and earlier), Windows ME, and Windows 2000 (and earlier) are not supported. Please do not try to install on these operating systems.

   1.2 Application compatibility:
You should not have any application installed on your system that is used by SYSmark 2004 SE. The application list can be found at Software Compatibility Notes. Please uninstall these applications before installing SYSmark 2004 SE.

   1.3 McAfee VirusScan:

Please make sure you do not have any version of McAfee VirusScan or any other anti-virus software on your machine.

If you are installing SYSmark 2004 SE on a system from which SYSmark 2004 was uninstalled, you may get an error prompting that VirusScan is already installed, though all files have been deleted. This is because a registry key may not have been deleted properly. If this happens, cancel the SYSmark 2004 SE installation. Run regedit and locate the key HKEY_LOCAL_MACHINE\Software\Network Associates\TVD\Shared Components\HAWK . Once this key is selected, right-click it and choose Permissions. Check the Full Control "Allow" checkbox, then click OK. Now delete the registry key by pressing the Delete key and confirm the action. This will also delete a sub-key "HAWKScript". Finally, close Regedit and start the SYSmark 2004 SE installation again.

   1.4 Systems with multiple drives or partitions:
SYSmark 2004 SE can be installed only in the system's Program Files directory. If one chooses to install SYSmark 2004 SE in a different folder, the folder has to be made the system's Program Files directory (not recommended).

   1.5 SYSmark 2004 SE compatibility:
SYSmark 2004 SE will not work properly if the system has one of the previous versions of SYSmark installed. It also will not work if you remove the previous versions of SYSmark using the Add/Remove program before installing SYSmark 2004 SE. Please install SYSmark 2004 SE on a clean system that doesn’t have any previous versions of SYSmark previously installed. SYSmark 2004 SE is different from SYSmark 2004; uninstalling SYSmark 2004 may not be sufficient to install SYSmark 2004 SE.

   1.6 Prompts at boot time:
Some systems are configured to automatically display a video or tutorial after boot up. Please disable any features such as this. If not corrected, this could cause the benchmark to fail or produce incorrect results.

   1.7 Installation on Japanese/Chinese OSes
Adobe Acrobat may not install properly on Operating Systems in Chinese and Japanese languages. This will cause the Office Productivity part of the benchmark to fail. There is no known solution except to re-do the installation from the start.

   1.8 User ID Requirements for installing and running SYSmark 2004 SE
You must be a user with administrative privileges to run and install SYSmark 2004 SE. You must run and install SYSmark 2004 SE with the same user ID. BAPCo recommends using the Administrator ID or creating a separate administrative user ID for the purposes of running SYSmark 2004 SE.

2.0 Benchmark Application Issues

   2.1 Office 2002 Document recovery.
Description: After any failure that results in Microsoft Word, Microsoft PowerPoint or Microsoft Excel closing abnormally, Microsoft Office will attempt a document recovery. This recovery results in a task pane appearing on the left-hand side of the Microsoft Office application, beginning at the next running of the application.
Workaround: After an abnormal closure, restart the system. After system boots up, start Microsoft Word by using the Start menu. Look on the left side of the application window. If a document recovery has been performed, you'll see a task pane with a list of documents. Move your cursor to the bottom of the task pane and select "Close". DO NOT RECOVER ANY DOCUMENTS. Answer "yes" to the query about having saved all the necessary documents. The document recovery task pane should disappear. Close the application. Perform the same set of tasks on Microsoft Excel and Microsoft PowerPoint.

   2.2 Excel 2002

Please refer to 2.1 Office 2002 Document recovery. No other known issue.

   2.3 PowerPoint 2002

Please refer to 2.1 Office 2002 Document recovery. No other known issue.

   2.4 Outlook 2002

      2.4.1 A dialog appears saying Outlook cannot locate a place to send and receive mail.
Description: Outlook cannot locate a place to send and receive mail.
Workaround: Installation did not properly install Outlook. This could stem from the application not installing certain parts if Office was previously installed on this machine. You must start with a clean (no Office installation) drive and install SYSmark 2004 normally.

      2.4.2 A dialog appears saying the BAPCo email services cannot be contacted and to go to the mail preferences and configure it.
Description: Same as 2.1.5.1
Workaround: Same as above

      2.4.3 Outlook error in SYSmark 2004 SE
Description: When SYSmark is used in certain time zones, there may be an error dialog in Outlook ("In Goto Date: can't find appointment window"). This error typically happens for systems in the GMT +7:00 to GMT +12:00 time zones. This error can be fixed by changing the Time Zone to GMT -08:00.
Workaround: 
1.) Close the benchmark and reboot the system
2.) Click on the "Date and Time" icon in the Control Panel (The Control Panel can be selected by clicking on the Start menu. On the Classic Start Menu the Control Panel can be found under the "Settings" menu.
3.) Go to the Time Zone tab
4.) In the top combo-list, select (GMT-08:00) Pacific Time (US and Canada); Tijuana
5.) Click on the OK button to confirm
6.) Reboot the system and run the benchmark again.

   2.5 Word 2002

Please refer to 2.1 Office 2002 Document recovery. No other known issue.

   2.6 Access 2002

      2.6.1 Access Deadlock Error
Description: During the run of Access 2002 an error may occur stating that "Access.pc6 failed because the 76 possible deadlock condition in Access_common.inc (..)
Workaround: This is an intermittent problem, with the only solution being running the test again. Please close all applications, NOT saving any content, if asked to. After acknowledging the script error, you can click on the "Retry" button, at the prompt. The benchmark will then try to run that scenario again.

      2.6.2 Access ImportData error
Description: During the run of Access 2002 in Windows XP an error may occur stating that " Access1.pc6 failed. The reason : On Main : ImportData script did not complete".
Workaround: This problem is seen on some recent systems. It is recomended to update the BIOS of the machine to its latest version.

   2.7 Naturally Speaking

      2.7.1 NaturallySpeaking crashes with an exception
Description: Dragon NaturallySpeaking exhibits an application error. During starting the application, or during a run, a Dragon NaturallySpeaking error window appears stating that a serious error or an exception has occurred. Left to run, a variety of script errors can result depending on the location of the failure. These errors will be displayed with the NaturallySpeaking application error obviously shown in the background.
Workaround: This is an intermittent problem, with the only solution being running the test again. When the dialog appears, click OK to close the dialog. A dialog asks to close all applications. Please do so. Then, when all applications are closed or stopped running, click OK. Finally, a second dialog asks to abort, retry or ignore, please click Retry.

   2.8 Internet Explorer

No known issues. Some issues seen with Internet Explorer are addressed with Flash and Dreamweaver application issues.

   2.9 WinZip

      2.9.1 Having WinZip pre-installed on the machine
Description: When running the benchmark, WinZip script returns the error "the zip file does not exist" or "file number 27 does not exist". This is linked to a previous installation of WinZip that was not properly removed.
Workaround: Exit the current run in the benchmark by acknowledging the benchmark error. At the "abort, retry, ignore" prompt, choose "Abort". Let the benchmark perform its cleanup and reboot the system. After the system has rebooted, open the system control panel and choose "add or remove programs". Choose the "WinZip SR-1 and Command Line Support add on" program choice. Click on the "Remove" button to remove the program from the system. Reboot the system. After reboot, go to the benchmark installation CD/source files and navigate to the \install\apps\WinZip81 directory. Double-click on the "WinZip81.msi" file. Follow the prompts, using the default choices to install the application. After the application has installed without error, you can run the benchmark normally.

   2.10 VirusScan

      2.10.1 Unexpected value, 11368 files read
Description:A SYSmark 2004 SE error is displayed, with the text : "The result read, 11368, does not match the expected value". This is typical of a system where Microsoft Office 2002 was previously installed and uninstalled, but some files and/or registry keys were left after uninstallation. This may happen if SYSmark 2002 has been uninstalled from the system
Workaround:It is necessary to take a disk with a clean operating system, with no previous installation of Office, and re-install SYSmark 2004 SE
      2.10.1 Result read does not match expected value
Description: VirusScan fails with the message " The result read, (number of files), does not match the expected value." Some files were not installed properly or are missing.
Workaround: This can be the result of file corruption during installation of the benchmark. Please contact BAPCo technical support for assistance in handling this error. A new installation of the benchmark on a clean operating system is recommended.

   2.11 Acrobat

      2.11.1 Acrobat PDFMaker scratch volume error during test run
Description: Office Productivity workload is interrupted in Acrobat PDFMaker for Word with this error: "Warning: Distiller's scratch volume is nearly full." A short while later, a SYSmark error message appears and the test fails.
Workaround: Close all applications and retry the test. This error occurs infrequently and seems to disappear on subsequent runs.

      2.11.2 SYSmark fails to install Adobe Distiller
Description: At the end of installation on Windows XP installed with Dutch language, SYSmark reports that Adobe Distiller component was not installed correctly.
Workaround: The error message could be incorrect. Ignore it and start a test. If the test passes, Adobe Distiller is installed correctly. If the test fails, please contact BAPCo technical support.

   2.12 Photoshop

      2.12.1 Photoshop Scratch Disk Error
Description: The benchmark fails returning the error "Adobe Photoshop: could not find application after starting". The Adobe Photoshop application is open with a "scratch disk" dialog displayed stating that the scratch disks are nearly full.
Workaround: This dialog can appear on rare occasions. Typically, the dialog indicates that the scratch disk (your boot disk) is full, despite plenty of space available. To avoid the error in the future, change the disk configuration in the scratch disk dialog, setting "First" to "C:\" and "Second" to "C:\". Next, verify that there is available space, as per the minimum system requirements for the benchmark, on the hard drive. If not, space must be freed up by eliminating files, without removing any related to the benchmark. After verifying available space, the benchmark can be retried. Click OK to close the SYSmark error dialog. A dialog asks to close all applications. Close the Adobe Photoshop application, after clicking "Cancel" on the scratch disk warning dialog. When all applications have closed or stopped running, click OK on the Close Application dialog. Finally, a second dialog asks to abort, retry or ignore, please click Retry.

      2.12.2 Photoshop Invalid Coordinates error
Description: The benchmark fails returning the error "Photoshop_main.pc6 failed. Unexpected error 74 Invalid coordinates for mouse event..".
Workaround: Please set the screen resolution to 1024x768 or greater.

   2.13 Premiere

      2.13.1 Premiere Project Initialization Error
Description: SYSmark 2004 has a minimum system requirement which includes a working soundcard. In the absence of a sound card (on-board or discrete with the proper drivers installed), an error with the warning “DV/IEEE 1394 play back & not setup correctly. Playback performance will be impacted” will appear.
Workaround: The system needs to have a sound card, discrete or integrated, enabled and with proper drivers installed.

      2.13.2 Premiere Codec error
Description: During Premiere execution, when the aplication tries to open a project, a Windows dialog box appears saying that a video Codec is required. The codec, which was installed and registered during the SYSmark 2004 SE setup, may be un-registered by a 3rd party applications.
Workaround: The user should register the codec again by following these 2 steps :
i. type 'cd \Windows\system32'.
ii. type 'regsvr32 ir50_32.dll'.

      2.13.3 Premiere Application error
Description: Adobe Premiere freezes during rendering. The Task Manager indicates that Adobe Premiere is not responding, sometimes with the application window contents replaced by solid white. Left to run, the benchmark usually returns an Adobe Premiere script error: "Progress window didn't disappear after 3600 seconds of rendering"
Workaround: This is an intermittent problem, with the only solution being to run the test again. When the dialog appears, click OK to close the dialog. A dialog asks to close all applications. Please do so. Then, when all applications are closed or stopped running, click OK. Finally, a second dialog asks to abort, retry or ignore, please click Retry.

   2.14 Dreamweaver

      2.14.1 Dreamweaver fatal exception during test run
Description: During the Dreamweaver workload, a dialog appears indicating a "Dreamweaver Fatal Exception". This causes the test to fail and produce another error message, the exact text of which is dependent on where the error happens to occur.
Workaround: This is an infrequent error. Close all applications and retry the test.

      2.14.2 Internet Content Creation workload fails in Dreamweaver.
Description: SYSmark fails at the beginning of the Internet Content Creation scenario. Dreamweaver MX is open and SYSmark reports this error message: "Unexpected error: 109 Active application will not enter menu mode".
Workaround: Close all open applications and retry the test.

      2.14.3 Dreamweaver fails with Internet Explorer.
Description: SYSmark fails with Dreamweaver MX and Internet Explorer open, and with Internet Explorer's Toolbar preventing the contents from being displayed.
Workaround: Close all open applications; open a Command Prompt and type "regsvr32 c:\windows\system32\macromed\flash\flash.OCX". THis will register the Flash AcitveX control.

   2.15 Flash

No known issues.

   2.16 3D Studio Max

No known issues.

   2.17 AfterEffects

No known issues.

   2.18 Media Encoder

No known issues.

3.0 General Issues

   3.1 Starting a run after a failure occurred.
Description: A failure has occurred in one of the applications of SYSmark 2004 and you wish to start a new run.
Workaround: The benchmark will not close applications that are open when a failure occurs. Close all applications manually, either by using their menu to close the application or by using the Task List to kill the application, before restarting a run if a failure occurs.

   3.2 Failure with a screen resolution change.
Description: The system suddenly experiences a video device failure which causes the screen resolution to be reset to the minimum (typically 640 x 480). This can occur during the run of any application in the benchmark. The benchmark script typically fails, usually the result of not being able to access a screen element.
Workaround: This is a rare occurrence, usually linked to a graphics driver stability issue. The solution is to try running the test again, after correcting the video resolution, and/or to update the graphics drivers. The minimum settings for the screen resolution are 1024x768 with 16 bits colors. Go to the Control Panel and choose "Display". Check that the proper video driver is configured for your system. If not, follow your manufacturer's instructions to set the proper video driver. Under the "Settings" tab, set the video resolution to at least the minimum resolution of 1024 x 768. Close the control panel after correcting the video resolution and driver. Close any open applications, not saving any content if asked. Acknowledge any SYSmark script error. At the "Abort, Retry, Ignore" dialog, you can choose to retry the test. The benchmark will start the test again.

   3.3 Windows Styles, DPI, font sizes
Both Classic and Default XP styles of windows appearance are supported. DPI settings of Normal (96) and Large size (120) are also supported. Other DPIs can be tested, but are not supported. It is strongly suggested to run the benchmark using the normal font sizes.

4.0 Uninstallation

No known issues